BURIED STRUCTURES - Tanks, Manholes, Wetwells, Soil Structure Interaction
- Conducted eight full-scale buckling tests on 10,000 gallon buried tanks with camera inside to verify local buckling and global buckling, developed new design methods for FRP USTs
- Conducted full scale float out test for 12,000 gallon UST for confirmation of buoyancy calculation method
- Conducted or witnessed Man Hole tests for conformance with ASTM D3753 for FRP Man Holes
- Designed tank upgrade for major FRP UST manufacturer to upgrade single wall tank to double wall tank in ground and received patent
- Performed numerous forensic investigations of FRP UST problems
- Provide guidance to manufacturers for testing new and existing products
|